121. An application appropriate for wall thichness measurement near surface |
A. focused angle probe |
B. standard single crystal probe |
C. TR probes |
D. high frequency vertical probe |
122. Inspection of oil rings is prescribed in codes written by |
A. AWS B. ASTM C. ASME D. Nuclear Regulatory Committee |
123. A circular disk flay much smaller than the wave length |
A. is likely to miss detection |
B. will reflect a spherical wave with pressure proportional to double the power of the flaw diameter |
C. will reflect a spherical wave with pressure proportional to the third power of the flaw diameter and |
inversely proportional to the wave length |
D. will reflect a spherical wave with pressure equal to the third power of flaw diameter |
124. Which NDT methods is best used to inspect to the inside diameter of thin wall tube? |
A. UT B. MT C. ECT D. PT |
125. When testing metal to rubber bond line from the metal side a strong indication for the metal |
thickness wouid indicate |
A. a good bond |
B. discontinuities in the metal |
C. discontinuities in the rubber |
D. lack of bond |
126. Which of the following is a factor in determining proper testing angle |
A. Attenuation |
B. Thickness of the part |
C. Resolution |
D. Sensitivity |
127. In testing ceramic materials using frequencies as high as 50Mhz the critical discontinuity size that |
can be defected is of the order of |
A. 2 milimeter(mm) B. 200 microns(μm) C. 20 microns(μm) D.2 microns(μm) |
128. pipe and tube are routinely UT tested by the shear wave method The sound beam should propagate |
what direction? |
A. circumferentially in two opposite direction |
B. Axially tin two opposite direction |
C. Both circumferentially and axially each in two opposite directions |
D. Both circumferentially and axially each in one opposite directions |
129. What will be the net effect on the ultrasonic beam when using contoured transducer shoes on the |
convex surface of round bar/tubes? |
A. Reduction of beam intensity at center of the sound beam |
B. Signal amplitude and sensitivity increase at periphery of the sound beam |
C. Reduction of beam intensity of periphery of the sound beam |
D. signal amplitude and sensitivity decreases of periphery of the sound beam |
130. A longitudinal ultrasonic wave is transmitted from water into steel at the angle of 9 degree from |
normal in such a case the refracted angle of the transducer wave is |
A. less than the refracted angle at the longitudinal wave |
B. equal to the refracted angle at the longitudinal wave |
C. greater than the refracted angle at the longitudinal wave |
D. not present at all |
131. Use of multiple transducer in UT testing results in |
A. couplant efficiency improvement |
B. slow down of test procedure |
C. improved discontinuity indication and characterization capability |
D. multiple indications being displayed |
132. What are two method of coupling? |
A. immersion and contact |
B. immersion and spray |
C. contact and spray |
D. brush and dip |
133. The effect of gold or silver electrode deposits on piezoelectric element? |
A. help enhance the generation of ultrasonic energy |
B. help reduce the voltage required to excite piezoelectric crystal vibration |
C. plating variations from 25 microns(μm) on some crystal have proven to effect |
D. only plating wariations greater than 25mm effect crystal performance |
134. When calibrating to perform an ultrasonic test it is best to have a surface condition? |
A. smoother than the test surface |
B. rougher than the test surface |
C. similar to the test surface |
D. same temperature as the test surface |
135. When performing angle beam testing for longitudinal discontinuities is a butt welded thick plate the |
minimum distance over which the transducer should be manipulated to assure coverage of the weld |
volume is? |
A. Two full skip distance |
B. One full skip distance |
C. Four T, where T is thickness of the weld |
D. Five T, where T is thickness of the weld |
136. when standardizing an immersion system for tubular products various techniques can be used to |
minimize testing inaccuracies caused by the curved entry surface. Which of the following |
combinations should provide the best test? |
A. A reference standard with a similarly entry surface and cylindrical focused transducer |
B. A reference standard with a similarly entry surface and a flat ultrasonic transducer |
C. A reference standard with a flat entry surface a unfocused transducer and curvature connection |
factor calculated from the critical diameter |
D. A notched reference standard and a spherically focused transducer |
137. You are mapping a pressure vessel for ID corrosion with a contact straight beam techniques |
indication are notched between 1/3 and 2/3 of the wall thickness. What would be the next |
recommended action? |
A. You would read the vessel's identification plate to make sure is was built per ASME codes |
B. It is common for vessel to have identification. No further evaluation is necessary |
C. The area with the indications shoul be mapped with a C-scan system and reported to the vessel owner |
D. Since you did have the inspection history of the vessel you compared the finding of the least time |
and decided since there was no change between the two inspection report to the owner |
138. Contact ultrasonic testing of full penetrations fillet welds in T -joint using the first leg of the second beam? |
A. will provide 100% volumetric inspection |
B. can detect or determine the extent of penetration |
C. can determine the lit up gap between welded plates |
D. cannot be conducted at all |
139. Which calibration block is best used for calibrating surface wave testing |
A. IIW Type 1 B. IIW Type II C. DSC block D. DC block |
140. An ultrasonic longitudinal wave travels in aluminum with a velocity of 635000cm/sec and has a |
frequency of one megahertz. The wavelength of this ultrasonic wave is |
A. 2.54cm B. 3.10cm C. 0.635mm D. 0.635cm |
answer
121 | 122 | 123 | 124 | 125 | 126 | 127 | 128 | 129 | 130 |
C | D | A | C | D | B | B | C | B | A |
131 | 132 | 133 | 134 | 135 | 136 | 137 | 138 | 139 | 140 |
C | C | A | C | B | A | C | B | D | D |