81. An effective and commonly used technique for measuring the through wall depth of a discontinuity in |
tubular products is |
A. a narrow focus shear wave transducer/wedge combination |
B. a highly dampened pitch-catch shear wave transducer/wedge combination |
C. a tandom pitch-catch shear wave transducer/wedge combination |
D. a multi-mode transducer/wedge shear/longitudinal transducer/wedge combination |
82. Surface wave methods might be used for aluminum plate inspection in addition to longitudinal wave |
testing methods because |
A. of the favorable grain structure at the surface due to the rolling process |
B. surface waves are especially sensitive to rolling induced discontinuities such as surface cracks and |
other surface blemishes |
C. of entry surface resolution |
D. difficulty in coupling |
83. Differences in performance between ultrasonic instruments and systems |
A. may be compensated for by use of the specified reference standards |
B. do not occur in modern equipment |
C. can be compensated for by adjusting to maintain the same background noise level |
D. seldom significantly affect the test results |
84. You are inspection An overlay of a welded steel pipe which you suspect has a columnar grain |
structure resulting from improper heat input and cooling during the welding process. What type of |
possible problems would you expect to encounter during shear wave ultrasonic testing of this weld? |
A. Inability to pass sound through the meterial at any frequency |
B. Re-direction of the sound beam |
C. Weld cracking at the root because of columnar structure |
D. None. Columnar grain structures are not possible in welds, only in castings |
85. The design "5-0300" on a distance amplitude reference block indicates that the block |
A. is 5 inches long with a hole diameter of 3/16 inch |
B. is 5 inches long with a hole diameter of 3/64 inch |
C. has a metal distance to the hole of 5 inches with a hole diameter of 3/64 inch |
D. has a metal distance to the hole of 3 inches with a hole diameter of 5/64 inch |
86. Under high ambient light conditions, increasing the pulse repetition rate may improve the brightness |
the "A" scan trace since the repetition rate control |
A. provides more voltage to the horizontal deflection plates of the scope |
B. increases the voltage of the pulser thus providing more power to the transducer |
C. increases the number of sweep inputs to the amplifiers of the scope with more over tracing of the |
same pattern of the CRT |
D. automatically increases the accelerating voltage in the CRT |
87. Which of the following modes of vibration will produce the shortest wavelength at a given frequency |
and in a given material? |
A. Thin rod wave |
B. Compression wave |
C. Shear wave |
D. Surface wave |
88. Personnel responsible for conducting ultrasonic tests should be |
A. trained and highly qualified and have a thechnical understanding of test equipment material and procedure |
B. trained to a higher level than quality assurance personnel |
C. able to understand and test to most common ultrasonic codes and specifications |
D. trained to ASNT/ANSI CP-189 |
89. Compact, digital-display thichness measurement instruments depend upon which of the following for |
their operating principles |
A. pulse-echo |
B. through-transmission |
C. resonance |
D. immersion |
90. Which of the following statements are true, when looking for a debonding condition between two |
materials whose acoustic impedance values vary significantly? |
A. Ultrasonics cannot be used due to the masking of debond signals by the interface signal |
B. A video presentation may improve results |
C. B-scan presentation may improve results |
D. A phases change may be detected at the acoustic interface when using RF displays |
91. During an ultrasonic test using the contact through transmission technique, there is a significant |
signal loss. Which of the following should be done when the signal loss is noticed? |
A. Check sensitivity setting of the ultrasonic instrument |
B. Check couplant, and apply more couplant if necessary |
C. Reinspect immediately with pulse echo |
D. Record and report indications and continue testing |
92. Surface wave techniques are often used in the testing of plate products because |
A. Surface waves are only effective on flat, rolled surfaces |
B. most plates are tested by immersion ultrasound and immersion transducers can easily be angulated |
to produce surface waves |
C. surface waves are very sensitive to shallow surface discontinuities induced by the rolling process |
D. surface wave testing takes the advantage of excellent entry surface resolution inherent in immersion |
pulse-echo testing |
93. In resonance thickness testing, what type of waves produce resonance? |
A. In-phase waves |
B. Multiple waves |
C. Single waves |
D. Standing waves |
94. An angle beam transducer producing a 45 degree shear wave beam in a low carbon alloy steel |
specimen would produce a shear wave angle in a aluminum specimen |
A. greater than 45 degrees |
B. less than 45 degrees |
C. 45 degrees |
D. surface waves only |
95. Which steel material interface would have the greatest impedance mismatch?(Steel is the first medium) |
A. Steel to lead |
B. Steel to plate glass |
C. Steel to copper |
D. Steel to nickel |
96. An indication is found during contact shear wave weld inspection by ultrasonics and is believed to be |
side wall lack of fusion. If the indication is lack of fusion, further analysis of the ultrasonic signal by |
orbital(rotating) the probe should result in |
A. a sudden amplitude drop |
B. very little amplitude drop |
C. a multi-faceted signal gradually increase in amplitude |
D. a broad signal gradually decreasing in amplitude |
97. When using a spherically focused sound wave for immersion testing, the sound enters the surface of |
an aluminum plate at an oblique angle. Which of the following statements is the most correct? |
A. The focal spot in the water is a shorter distance than the plate |
B. The focal spot in the plate is a shorter distance than in the water |
C. The focal spot in the plate is the same distance as in the water |
D. The plate surface acts as a lens that is less powerful than the acoustic lens |
98. An indirect pitch and catch test has been developed for weld discontinuities. The transmitting |
transducer is inclined at an angle that produces 60 degree refracted shear wave. The receiving |
transducer is positioned normal to the test object surface and defects the scattered waves. This |
technique is known as |
A. tandom transducer test |
B. indirect pitch and catch test |
C. time of flight diffraction test |
D. Delta technique test |
99. Calibration standards generally used for ultrasonic examination of metal tubing for longitudinal |
discontinuities contain |
A. side-drilled holes |
B. flat-bottom holes |
C. notches of slots |
D. gaps |
100. Ultrasonic testing and acceptance of forged raw stock prior to machining to it’s final form is a |
common practice because |
A. machined parts are typically tested by visual inspection |
B. tests are frequently more difficult due to dead zones and structural reflections after machining |
C. the forged parts are generally too small to test easily after machining |
D. the sound wave generates the forging better than after it has cooled completely |
answer
81 | 82 | 83 | 84 | 85 | 86 | 87 | 88 | 89 | 90 |
C | B | A | B | D | C | D | A | C | D |
91 | 92 | 93 | 94 | 95 | 96 | 97 | 98 | 99 | 100 |
B | C | D | B | B | A | B | D | C | B |