181. For a longitudinal immersion test, an automatic scanner is set to scan at 50cm/sec with a pulse |
repetition rate of 500 pulses per second and the water path is 25cm over an aluminum plate. |
Assuming an effective beam diameter of 0.220cm at the depth of the flaw, on the average how many |
effective interrogation would be made during one scan over a flaw equivalent to a flat-bottomed hole |
0.0397cm in diameter? |
A. 1.5 B. 2.2 C. 4.4 D. greater than 5 |
182. A remote testing application using air couplied ultrasonic that would be more practical than using |
conventional ultrasonic method is |
A. testing composites for thickness |
B. testing thin sheet for thickness at elevated temperatures |
C. testing wood composites for determinations |
D. testing ball bearings for roundness |
183. A back echo gate is required to be set during the calibration of ultrasonic equipment for an automated |
immersion, longitudinal beam inspection of the plate, The function of the back echo gate for this |
calibration is to alarm on _______________________ |
A. an increase in the back echo signal due to changes in perpendicularity and/or water path |
B. a drop in the back echo signal due to lack of perpendicularity or excessive |
C. the absence of a back echo signal due to the change in water path |
D. a drop in the back echo signal to provide a base line (back reflection amplitude) |
for the C-scan data generated by the system directonics |
184. Which of the following methods of flaw sizing are capable of accurately measuring the plane |
flaw size of 10 I.D cracks? |
A. flaw tip diffraction method |
B. decibel drop mothod |
C. high angle shear wave |
D. through transmission |
185. The ultrasonic A-scan response from a composite tubing discontinuity gives the appearance of |
reflections original at the tubing surface over the discontinuity. The difference between the discontinuity |
reflection and the front surface reflection depends on the depth of the discontinuity. The discontinuity |
would be classified as |
A. a resin starved layer |
B. a lack of roving |
C. concealed cut |
D. impact damage |
186. The amplitude of an acoustic signal is expressed in |
A. Hertz B. decibels C. radians D. newtons |
187. A 2 inch steel plate with a smooth shiny surface is being tested by a longitudinal ultrasonic beam. |
An indication is found that appears between the front surface and back surface reflections. This |
indication remains uniform in shape and magnitude when the transducer is moved around the edge of |
the plate. Which of the following is the most plausible explanation for this indication? |
A. The indication is form a lamination extending around the perimeter of the plate |
B. the ultrasonic instruments pulse repetition rate is set too high causing a false indication |
C. the indication is form the plate corner caused by the transducers beam spread |
D. surface waves are being reflected from the edge, causing a false indication |
188. In contact manual pulse echo ultrasonic testing. The width of the initial pulse may vary from the |
calibration block to the test surface due to |
A. increased damping efficiency of the transducer |
B. the use of thick couplant layers or the presence of rough entry surfaces |
C. decreasing of the pulse duration |
D. the use of lower pulse frequencies |
189. For immersion ultrasonic testing, precision steel balls are used as target reflects for measuring certain |
inspection system characteristics. Which of the characteristics below is not measured by using |
precision steel balls? |
A. beam symmetry |
B. transducer operating frequency |
C. horizontal limit |
D. focal distance in water |
190. The use of projected distance in calibration for shear wave inspection permits the operator to |
A. calibrate in unite of length of the actual sound path |
B. calibrate in unite of part thickness |
C. calibrate in units of length related to surface of specimen |
D. calibrate without the use of a known thickness standard |
191. The calibration standard for pipe and tubular products should contain two longitudinal notches |
(one on the inside surface and one on the outside surface) and two circumferential notches(one on the |
inside surface and one on the outside surface) Unless otherwise specified. The notches should have |
a maximum depth of |
A. 3 percent of the nominal wall thickness or 0.1mm, whichever is greater |
B. 5 percent of the nominal wall thickness or 0.1mm, whichever is greater |
C. 6 percent of the nominal wall thickness or 0.2mm, whichever is greater |
D. 10 percent of the nominal wall thickness or 0.2mm, whichever is greater |
192. A decreased of 2 degrees in a plexiglass wedge will change a 45 degree show wave angle in steel |
by appropriately |
A. 4 degrees |
B. 3 degrees |
C. 6 degrees |
D. 8 degrees |
193. Frequency specified in cycles unit time in non-S1 units can also be expressed in Sl units |
A. decibels |
B. lux |
C. Hertz |
D. ~~~~~ |
194. It the angle of incidence during the performance of an immersion test of a type 410 stainless steel |
plate was found to be 33 degrees, which mode(s) would exist in the plate? |
A. Longitudinal wave |
B. Shear wave |
C. Surface (Rayleigh) wave |
D. Creeping wave |
195. During a shear wave test on an aluminum weld it was carefully determined that the response time |
from a discontinuity was equal to 5.25 microseconds. What is the metal travel distance to the defect? |
A. 1.02 cm |
B. 1.63 cm |
C. 16.6 cm |
D. 24.4 cm |
196. During a test using A-scan equipment strong vertical indications that move at varying rates across the |
screen in the horizontal direction appear. lt is impossible to repeat a particular screen pattern by scanning |
the same area. A possible cause of these indications is |
A. porosity in the test part |
B. an irregularly-shaped crack |
C. a large grain structure |
D. electrical interference |
197. Focused transducers are especially useful in performing ultrasonic testing on |
A. tick sections of material |
B. complex configurations |
C. porous materials |
D. high resolution examinations |
198. Forging of irregular shape can be given a practically complete inspection including fillet areas by |
A. ultrasonic contact testing |
B. ultrasonic immersion testing |
C. ultrasonic resonance testing |
D. ultrasonic through-transmission testing |
199. Difficulties may be encountered when a "C" scan is made during a shear wave immersion test because |
A. the velocity shift from longitudinal to shear wave makes calibration uncertain |
B. slow velocity of the shear wave requires slow scan rates |
C. interface synchronization may not be possible for grating |
D. focusing is distorted due toe the incident angle |
200. When testing composite materials, one factor to consider when designing a test is the attenuation |
factor of the material, In metal matrix composites, the attenuation of the materials is generally |
A. much higher than base metals |
B. much higher than organic composites |
C. between that of fiber composites and refractory composites |
D. between that of base metals and organic composite |
answer
181 | 182 | 183 | 184 | 185 | 186 | 187 | 188 | 189 | 190 |
B | C | C | A | A | B | C | B | B | A |
191 | 192 | 193 | 194 | 195 | 196 | 197 | 198 | 199 | 200 |
B | D | C | D | C | D | D | B | A | D |
728x90
반응형
'inspection > ASNT L3' 카테고리의 다른 글
QUIZ) ASNT L3 UT 12 (0) | 2020.06.24 |
---|---|
QUIZ) ASNT L3 UT 11 (0) | 2020.06.24 |
QUIZ) ASNT L3 UT 9 (0) | 2020.06.24 |
QUIZ) ASNT L3 UT 8 (0) | 2020.06.24 |
QUIZ) ASNT L3 UT 7 (0) | 2020.06.24 |