21. When establishing a magnetic particle procedure for a part to be used in a specific application, there are |
many parameters that should be included in the procedure. Of the items listed below, which one has no |
appreciable effect on the inspection results? |
A. Type of magnetic particles |
B. Type and amount of applied current |
C. Direction of magnetizing field |
D. Reference to applicable standards |
22. When magnetic particle testing a welded pipe made from high alloy ferritic steel, a broad fuzzy, loosely |
adhere indication show in the heat affected zone along the full length of the weld. Which of the |
following best describes the probable cause of the indication? |
A. Surface cracks |
B. Permeability change at the heat affected zones |
C. Lack of penetration |
D. Geometry of the weld |
23. Which type of magnetization device would you rather specify in cases where a large number of the |
same test objects with very complicated geometries would to be fully magnetic particle tested |
A. One circular shot along the largest current path through the part |
B. One longitudinal shot along the largest path through the part |
C. Two shot though the shortest path, one circular, one longitudinal |
D. Multiple path magnetization, circular and longitudinal |
24. Which type of magnetizing current would be best suited to find surface and subsurface discontinuities |
with dry magnetic particles? |
A. Direct current |
B. Alternating current |
C. Half-wave rectified alternating current |
D. Full-wave rectified alternating current |
25. Specifying a capacitor discharge/central conductor system for adequate magnetization of oil field tubular |
or other long pipe, requires |
A. no prior knowledge of the nature of the tubular product |
B. a knowledge of the physical dimensions of the tubular product |
C. a knowledge of the physical, electrical, and magnetic properties of the tubular product |
D. the use of an impedance plane diagram and Foerster’s "limit frequency" equation |
26. Which of the following is the most acceptable method of demagnetizing a part with a high quality |
surface finish? |
A. Head shot with AC |
B. Alternating current coil with reducing current or withdrawing the part with the coil at constantcurrent |
C. Head shot with DC step-down reversing current |
D. AC yoke |
27. A symmetrical hollow conductor of magnetic material is carrying direct current of same specified value |
resulting in a field strength value of F on the outside surface. The tube is 2 inch O.D and 1 inch I.D. The |
field strength at the inside surface of the conductor is |
A. F/2 |
B. near zero |
C. F/3 |
D. F/4 |
28. A magnetic particle examination must be performed to most effectively detect fatigue cracks in a |
camshaft. The best selection is |
A. direct current to obtain the most even distribution of field strength through the part |
B. direct current to produce the highest concentration of field strength in the corners where cracks are more |
likely to occur |
C. alternating current because of the ease of demagnetization which is needed for rotating parts |
D. alternating current to obtain the most even surface distribution of field strength following the contour |
of the part |
29. Wet bath magnetic particles have |
A. lower retentivity than dry particles |
B. different shape than dry particles |
C. about the same coercive force as dry particles |
D. lower coercive force than dry particles |
30. The subsurface discontinuity most likely detected using magnetic particle examination of material |
following primary processing is: |
A. seams |
B. forging laps |
C. stringers |
D. lamination |
31. in coil magnetization is the ratio of the cross sectional area of the object within the coil to the |
cross-sectional area of the coil |
A. Fill factor |
B. Effective field |
C. Flux lines |
D. Magnetic domains |
32. Which type of the magnetizing current would be the most effective to find subsurface discontinuities? |
A. Direct current |
B. Alternating current |
C. Half-wave rectified alternating current |
D. Full-wave rectified alternating current |
33. Which of the following methods of particle application must be employed when performing |
multidirectional magnetism? |
A. Wet method |
B. Dry method |
C. Continuous method |
D. Residual method |
34. A cylindrical part is to be tested using a headshot. The part has three different diameters along its length |
The current level(s) would be based on |
A. the largest diameter |
B. the average diameter |
C. each individual diameter |
D. the L/D ratio for each section |
35. When the current is doubled in a solid non-magnetic conductor the field strength at the |
A. surface decreases to 1/2 the original |
B. surface increases by a factor of two |
C. center is increased by a factor of two |
D. surface and center does not change |
36. The most through method for insuring the removal residual magnetism is |
A. heating the part above its curie point |
B. AC coil demagnetization |
C. reversing DC demagnetization |
D. oscillating current demagnetization |
37. Which of the following the least important reason for demagnetization of a material is that residual |
magnetism can |
A. interfere with welding |
B. attract small metallic particles |
C interfere with subsequent fabrication processes |
D. interfere with electrostatic painting processes |
38. Wet nonfluorescent particles are normally |
A. pigmented in various colors |
B. non pigmented ferromagnetic iron oxides |
C. are made as fluorescent particles then have the fluorescent pigment removed |
D. less sensitive than dry particles |
39. Using alternating current to demagnetize a large cross-section object will often prove ineffective because |
A. AC is ineffective on small cross-section parts |
B. the part may not be perpendicular to the earth’s magnetic field |
C. large AC coils require high currents |
D. of the associated skin effect with AC |
40. A magnetic particle technique used to interrogate the area affected by flux lines at the ends of |
longitudinally magnetized test parts is referred as |
A. parallel magnetization |
B. multidirectional magnetization |
C. induced longitudinal magnetization |
D. quick break magnetization |
answer
21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 |
D | B | D | C | C | B | B | D | C | C |
31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 |
A | C | C | C | B | A | D | B | D | C |