728x90
반응형
41. The bulk indicator is designed and normally used for an assessment of magnetic leakage fields as a |
practical check on the external demagnetization state of an object. The indicators commonly used for |
checking external field levels after a magnetic particle test normally have a range of about 1 to 2mT |
(10 to 20 Gauss). Positive and negative readings represent which pole? |
A. Positive readings represent north and negative readings represent south |
B. Positive readings represent south and negative readings represent north |
C. Negative readings represent 10 Gauss and positive readings represent 20 Gauss |
D. Readings are in reference to a differential magnetic field and do not represents poles |
42. Assuming operators are fully qualified which is the best means of insuring consistent part processing in |
spite of operator differences? |
A. Having a detailed written procedure for each type of part to be processed |
B. Having an approved operator training and certification program |
C. Periodic supervisory observation of operators at work |
D. Having a requirement that each operator be certified as being qualified at Levels I or II in accordance |
with SNT-TC-1A |
43. Non relevant indications may be caused by |
A. fatigue cracks |
B. lack of fusion at a weld surface |
C. a casting defect |
D. part geometry |
44. The set-up of a production magnetic particle inspection line is usually limited to or restricted by the |
A. material composition |
B. part size |
C. acceptance standards |
D. heat treatment specified |
45. An aircraft quality 3 inch(I.D) steel cadmium plated nut was cut in half using a fluid regulated circular |
saw for visual examination of the plating cross section. Upon close inspection no buring was seen on the |
cutting surface of the nuts. The plating condition of the halves was wavy or ripply in appearance. It was |
noticed that two(2) nut halves were highly magnetized and stuck like two(2) horseshoe magnets when put |
together. This over magnetized condition could have been caused by |
A. the circular cutting action of the saw usage |
B. the plating process in which the cadmium coat or layer was applied |
C. since the nut was aircraft quality the over magnetized condition could have been caused by a previous |
step in which the nut was magnetic particle inspected leaving a residual field undetected |
D. the magnetic properties typical of 4130 steel |
46. circular magnetization will detect most discontinuities that |
A. are between forty-five and ninety degrees to the line of force |
B. are between zero and forty-five degrees to the line of force |
C. contain a north and south pole with flux leakage |
D. are subsurface and parallel to the axis of the flux leakage force |
47. When performing circular magnetization with prods a prod spacing at less than 3 inches(75mm) is not |
practical because |
A. localized heating causes the particles to clump together |
B. the particles tend to band around the prods making interpretation difficult |
C. the prods may touch causing arcing |
D. the magnetic particles cannot be applied to this small space |
48. The sudden breaking of a direct current which causes a transient current to be induced is referred to as |
A. parallel magnetization |
B. multidirectional magnetization |
C. induced longitudinal magnetization |
D. quick break magnetization |
49. When two or more magnetizing forces operating in difficult directions are simultaneously applied to a |
ferromagnetic material a field is produced having a direction which is determined by the relative |
strengths and directions of the applied magnetic forces. Such a field is called a |
A. distorted field |
B. longitudinal field |
C. trigonometric or theoretical field |
D. resultant or vector field |
50. When using prods which one of the following discontinuities could be detected? |
A. A discontinuity with the major direction lying transverse to an imaginary line drawn between the prods |
B. A discontinuity with the major direction lying parallel to an imaginary line drawn between the prods |
C. Discontinuities cannot be detected in this manner |
D. A discontinuity which lies in a direction perpendicular to the cable attached to the controlling prod |
51. To provide an adequate magnetic field produced by a coil how many ampere-turns are required on a |
part 16 inches long and 2 inches in diameter when the part is placed in the center line of a coil having |
a diameter of 10" and u over 500? |
A. 9,000 ampere-turns |
B. 5,625 ampere-turns |
C. 2,812 ampere-turns |
D. 5,000 ampere-turns |
52. The term given to magnetization of a material such that the magnetic flux runs substantially parallel to |
the part with the flux path completing itself through the air outside the material and having at least |
two external poles exist is |
A. parallel magnetization |
B. circular magnetization |
C. longitudinal magnetization |
D. vectored magnetization |
53. The test used to check the particle concentration of the wet inspection method bath is called |
A. sensitivity test |
B. setting test |
C. hydrometer test |
D. settling test |
54. Which of the following factors need not be considered in establishing acceptance criteria for magnetic |
materials inspected by the magnetic particle method? |
A. Design requirements |
B. Service environment |
C. Orientation of indications |
D. Permeability of material |
55. Determine the cross sectional area of a 16" diameter coil |
A. 8 square inches |
B. 64 square inches |
C. 128 square inches |
D. 201 square inches |
56. Prolonged or repeated periods of magnetization are often necessary for polymer or slurry base |
suspensions because |
A. it is harder to magnetize |
B. it takes longer to magnetize |
C. of slower inherent magnetic particle mobility in the high viscosity vehicles |
D. of inherent particle mobility in the low viscosity vehicles |
57. If wet particles that posses high coercive force are used they many become highly magnetized and form |
objectionable |
A. fluorescence |
B. background |
C. indications |
D. magnetic writing |
58. What is the maximum recommended amperage value for a part with a thickness of 1.2 inches and a prod |
spacing of 5 inches when 100 to 125 amps / in of prod spacing is required? |
A. 550 Amps |
B. 500 Amps |
C. 450 Amps |
D. 625 Amps |
59. Ultraviolet lamps should be connected to a constant voltage supply to |
A. minimize intensity variations |
B. maximize intensity variations |
C. reduce bulb life |
D. stabilize the wave length |
60. In magnetizing a 1.5 inch diameter tube having a 0.125 inch wall with direct conduction and direct |
current at 1500 amps, what is the field strength on the internal diameter? |
A. Zero |
B. Same as outside |
C. Fifty percent of theoretical field strength |
D. Approximately 150 oerstads |
answer
41 | 42 | 43 | 44 | 45 | 46 | 47 | 48 | 49 | 50 |
A | D | D | B | C | A | B | D | D | A |
51 | 52 | 53 | 54 | 55 | 56 | 57 | 58 | 59 | 60 |
B | C | D | D | D | C | B | D | A | A |