401. electrical discharge machining is useful in nondestructive testing because it can prodece |
a. fine surface finishes |
b. small hole’s and notches |
c. sharp reductions in cross section area |
d. natural flows for precision calibration blocks |
402. an industrial fiber-optic borescope will have which of the following component? |
a. rigid tubes joining the lenses in the system |
b. copper wires to transmit the electrons origginating in the sensor unit of the borescope |
c. polished glass tubes |
d. clad glass strands |
403. the primary function in radiographic interpretation is to find |
a. all fissures associated with the part |
b. discontinuities which adversely affect use of the part |
c. structural and mechanical weaknesses |
d. indications which exceed minimum penetrameter hole sizes |
404. the experience records required to be maintained in accordance with CP-189 |
a. need only address initial certification requirements |
b. must be updated monthly |
c. must verity initial and continuing experience by method and by hour |
d. do not require a minimum number if hours worked in a specific method |
405. if the radiation intensity 25 feet from an Ir-192 radiation source is 200mR/hr what intensity |
a. 2mR/hr b. 5.55 mR/hr c. 25 mR/hr d. 33.33 mR/hr |
406. which of the following is true regarding the investment or _ casting process? |
a. tolerances are typical plus or minus 1/16" |
b. pre entrant cannot be produced during casting and must be machined later |
c. large casting up to 8 feet in diometer are easily produced |
d. in many cose to lerances are sufficient without further machining |
407. in the forging processing excess metal that must be removed by secondary operation is called |
a. dross b. flakes c. flash d. bursts |
408. a hall-effect meter is used to measure |
a. radiation level |
b. flux density |
c. ultrasonic frequency |
d. the rate of acoustic emissions |
409. The basic levels of qualification recognized by CP-189 are? |
a. Trainee, Level I, Level II, Level III, NDT Instructor |
b. Level I, Level II, Level III |
c. Level I, Level II |
410. in evaluating qualification in accordance with SNT-TC-1A you find that an individual has limited familiarity |
with the method in which certification is shought. What action should you take? |
a. issue a limited certification |
b. require additional training |
c. require additional experience |
d. follow employers written practice |
411. post-emulsitied penetrant processes require for penetrant removal |
a. no additional emulsifier |
b. separate emulsifier |
c. addition of solvents |
d. no water |
412. a new employer with no prior NDT experience has successfully completed a 6 hour liquid penetrant training |
program they also have documented 230 hours of work experience in PT. this candidate for certification |
a. may be certified as PT level I maximum |
b. may be certified as PT level II maximum |
c. may be certified as PT level level III |
d. cannot be certified because he/she does not fulfill the requirements |
413. a surface condition produced during casting of an ingot. Caused by hot molten metal splashing on the |
mold surface is called a |
a. bloom b. plping c. blowhole d. scab |
414. in accordance with SNT-TC-1A an individual may be recertified to the former level of certification after |
termination of employment and upon employment with a new employer without additional training provided |
the individual |
a. holds a valid ASNT NDT level III certificate |
b. is being recertified within six month of termination |
c. has been certified as at least a level II or level III b the previous employer |
d. has been certified as a level III by their previous employer |
415. Compliance to CP-189 is mandatory when? |
a. the material being tested is for a U.S. Air Force contract |
b. the inspection is being performed at a goverment-controlled facility |
c. it has been specified by the customer |
416. what is the maximum recommend kV that should be used in the pinhole projection method of measufing |
focal spot size? |
a. 300 kV b. 600 kV c. 900 kV d. 1200 kV |
417. the proportional relationship between measured gamma-ray tuteusity and number of curies does not hole |
for large physical source sizes with low specific activities because of |
a. self-absorption |
b. build up |
c. internal decay |
d. fission losses |
418. which of the following cannot be determined by gaging with an appropriate radiation source and detector? |
a. material density |
b. material thickness |
c. hydrogen content |
d. surface strain |
419. A blooming mill is a |
a. machine for cold-rolling to produce sheet metal |
b. machine for hot-rolling of ingots |
c. machine for hammer-forging in closed dies |
d. machine for press-forging in open dies |
420. CP-189 contains the definition of an "NDT instructor" according to SNT-TC-1A, The NDT instructor is |
a. defined but dose not have to be qualified and designated as in CP-189 |
b. defined and must be qualified and designated as in CP-189 |
c. not defined |
d. not defined and cannot be used in the employer's written practice |
ANSWER
401 | 402 | 403 | 404 | 405 | 406 | 407 | 408 | 409 | 410 |
B | A | B | C | B | D | C | B | A | A |
411 | 412 | 413 | 414 | 415 | 416 | 417 | 418 | 419 | 420 |
B | B | D | B | C | A | A | D | B | C |